How to Plan Elevators for Mixed-Use Developments in Saudi Arabia

Planning elevators for a mixed-use development in Saudi Arabia starts with the people who will use the building. Homes, offices, hotels and retail areas can create different travel patterns within the same tower. The aim is to identify those conflicts before the number of shafts and the size of the lobbies are fixed.

A useful design brief covers five decisions: user groups, shared or separate cores, traffic performance, service and fire requirements, and the equipment environment. These decisions also help suppliers prepare comparable proposals.

1. Map each user group and its peak periods

List residents, office workers, hotel guests, shoppers, visitors and service staff separately. Record the floors they use, their entry points, access restrictions and likely busy periods.

For a Saudi project, ask the operator how Ramadan opening hours, prayer-related movements, weekend trading and events could affect demand. A hotel near a major destination may have different traffic from a business hotel. Use the actual operating plan rather than assuming every building follows the same pattern.

  • Include basement parking and other entrance levels.
  • Allow for luggage, wheelchairs, strollers and deliveries.
  • Check whether public, residential and service traffic overlap.
  • Record expected occupancy at opening and after full letting.

2. Compare shared and separate elevator cores

Separate groups can make access control and privacy easier to manage. Shared groups can reduce the space allocated to shafts, but their performance depends on the combined demand and the control strategy.

Arrangement Potential benefit Question to resolve
Separate residential, hotel and office groups Clear access routes and operating responsibilities Is the additional shaft and lobby space justified?
Shared passenger group More flexible use of a common core Can it handle overlapping peaks without compromising access?
Separate service route Less conflict between passengers and deliveries How will goods reach each use without crossing sensitive areas?

There is no universal arrangement for every development. Compare options with the architect, operator and vertical-transportation consultant. Review the access-control interface alongside the elevator dispatch strategy.

3. Size the system with a traffic study

A rule such as one elevator per fixed number of apartments can help an early discussion, but it is not a substitute for a project traffic study. Agree the performance criteria, then assess the number of cars, capacity, speed, stops and control system together.

ISO 8100-32 addresses passenger-lift planning for office, hotel and residential buildings. Its mixed-use scope has conditions, so the consultant should select a suitable calculation or simulation method for the actual combination of uses.

Test the difficult periods, such as office departures overlapping with retail arrivals. Include service interruptions and the effect of one car being unavailable when assessing operating resilience.

4. Coordinate service and fire requirements early

Identify delivery, waste, furniture and maintenance routes before finalizing car sizes and door openings. Where stretcher access or other special functions are required, have the design team define them explicitly.

The fire consultant should establish the applicable code edition, building classification and authority requirements. The Saudi General Building Code is a starting reference for the wider building design. Confirm how the approved fire strategy affects shafts, lobbies, recall, emergency power and any designated fire-service or evacuation lifts.

5. Confirm the environment and delivery responsibilities

Request the selected equipment’s temperature and humidity limits, heat output and protection requirements. The building-services design must account for the actual site climate, dust exposure and cooling arrangements.

Separate equipment supply from installation, commissioning, inspection and maintenance in the tender. Identify who performs each activity and what documentation is needed. A manufacturer quotation should not be treated as evidence of a local service team unless that scope is expressly confirmed.

Prepare a comparable supplier brief

Send bidders the building use, location, floor schedule, traffic-study requirements, shaft drawings, access-control brief and approved fire strategy. Ask them to state assumptions, exclusions and the information still needed.

FUJIHD is a China-based elevator manufacturer. Explore the FUJI elevator range and related commercial elevator solutions when developing your equipment shortlist. To discuss a Saudi mixed-use project, send FUJIHD your project brief and drawings; configuration, documentation and supply responsibilities can then be confirmed for the quotation.

Share this post
Facebook
Twitter
LinkedIn

Contact Us

We respect your privacy When you provide your contact information, we only agree to contact you in accordance with our privacy policy.