What Happens to an Elevator When the Power Goes Out?

A power outage normally stops an elevator. Loss of the electrical supply alone is not the same as a failure of the car’s support or holding systems. What happens next depends on the lift type, its condition and the rescue or backup equipment installed.

Some lifts can move passengers to a landing using a dedicated rescue system. Others remain stopped until power is restored or trained personnel assist. Here is what passengers and building owners should know.

Why an elevator normally stops in a power cut

In a conventional traction lift, the braking system is designed to hold the car when drive power is removed. A hydraulic lift uses a different arrangement, with valves controlling the movement of oil and the car. The operating sequence must be assessed for the particular installation; not every lift has the same equipment.

Emergency lighting and communication systems may have a separate battery supply. Their availability depends on the installed equipment, battery condition and communication connection, so owners should test them rather than assume they will always work.

What happens next depends on the lift

Lifts with an automatic rescue device

An automatic rescue device, or ARD, can provide the power needed for a controlled rescue movement after a supply failure. If the required safety conditions are met, the system brings the car to an appropriate landing and operates the doors so passengers can leave. The permitted direction, landing and sequence depend on the controller and rescue system.

An ARD is generally intended to release passengers, not to keep the lift running normally throughout the outage. Confirm whether this function is included when reviewing FUJI elevator specifications. The FHSP50 product page lists a battery-powered return function under optional functions; the exact quoted configuration and approved operating instructions must be checked.

Hydraulic lifts

Some hydraulic lifts have an emergency lowering system that allows controlled descent to a landing during a power failure. The destination and door operation depend on the equipment. It is incorrect to assume that a hydraulic lift must first travel upward before it can lower. Manual release or lowering procedures belong to trained, authorized personnel.

Lifts without an operating rescue system

If no suitable backup or rescue system is available, a stopped car may remain between floors. Passengers should use the emergency communication equipment and wait for qualified assistance. Restoring power may not be enough to return every installation to service; inspection or a controlled reset can be necessary.

Buildings with a generator

A standby generator can support elevator operation only if the building’s electrical system and lift controls have been designed for it. The approved sequence may return cars in stages or keep selected lifts available. Capacity, starting demands and compatibility need coordinated design; connecting a generator does not automatically make every lift usable.

What to do if you are stuck

  1. Stay inside the car and keep clear of the doors.
  2. Use the alarm, emergency telephone or intercom. Give the building location, lift identification, number of passengers and any urgent medical needs.
  3. If communication equipment does not work and you can use a mobile phone, contact building management or local emergency services as appropriate.
  4. Follow instructions from trained responders and wait for assistance.

Do not force the doors, climb out between floors or attempt to leave through a hatch. The University of Illinois Chicago’s elevator entrapment guidance also advises staying in the car, requesting assistance and avoiding self-rescue. If a rescue system brings the car to a landing and opens the doors normally, check the floor level and exit carefully.

What building owners should check

  • Which rescue or backup system is installed on each lift, and what is its documented operating sequence?
  • Are emergency lighting, alarm and communication batteries tested and replaced according to the maintenance requirements?
  • Who receives emergency calls, and how are unanswered calls escalated?
  • Who is authorized to rescue passengers and restore the lift to service?
  • Is the generator interface included in the testing plan where standby power is provided?
  • Are rescue functions and battery maintenance explicitly covered in the service contract?

Specifying backup arrangements

Ask for the rescue function, battery maintenance needs, exclusions and commissioning checks in writing. A product description should distinguish passenger release from continued operation during an outage, and identify the responsibilities of the lift supplier, electrical contractor and maintenance provider.

For a new project, contact FUJIHD with the building use and proposed power arrangement to discuss the equipment scope. Availability and performance of rescue features must be confirmed for the quoted configuration.

Share this post