An automatic rescue device, or ARD, is a system intended to help release passengers after an elevator loses its normal electrical supply. When the required operating and safety conditions are met, it uses a backup source to move the car to an appropriate landing and allow the doors to open.
It is a useful feature to discuss during procurement, but it should not be assumed to be included in every lift. When comparing FUJI elevator configurations, ask the supplier to identify the rescue equipment and its scope in the quotation.
How an automatic rescue device works
The exact sequence varies by controller and rescue system. A typical arrangement monitors the normal supply and keeps its backup batteries charged. After a qualifying power failure, the controller checks whether rescue operation is permitted and carries out a controlled movement.
- The system detects the power failure and applies its configured checks.
- It confirms that the relevant safety and operating conditions allow movement.
- It supplies the equipment needed to move the car toward a permitted landing.
- It levels the car and operates the doors according to the rescue sequence.
- The lift remains in the state specified by its controller until normal service can be restored.
Rescue speed, delay, travel distance and battery capability are equipment-specific. Do not use a general time estimate as a guarantee that every passenger will be released within a fixed number of seconds.
Why the direction of travel can vary
A traction elevator’s car and counterweight are connected through the suspension system. Depending on the load balance and rescue design, moving in one direction may require less energy than moving in the other. Some systems use this relationship when choosing the rescue direction.
This does not mean every ARD always goes down or always reaches the physically closest floor. Ask which landing the proposed system can serve, how direction is selected and what conditions can prevent the rescue movement. The answer should match the actual drive and controller documentation.
ARD vs UPS vs generator
| System | Typical role | What to confirm |
|---|---|---|
| Automatic rescue device | A controlled movement that allows passengers to leave after loss of normal power. | Supported lift configuration, rescue sequence, usable battery capacity and conditions that inhibit operation. |
| UPS or other battery backup | Power for specified loads and a defined duration; its role depends on the design. | Whether it powers only controls, supports a rescue trip, or is engineered for continued lift operation. |
| Building generator | Standby power for selected building services, potentially including lifts. | Electrical compatibility, transfer arrangements, load capacity and the approved lift operating sequence. |
The name “UPS” alone does not establish that a lift will continue operating normally. Likewise, an ARD is not a substitute for a generator where ongoing service during an outage is part of the project requirement.
What an ARD cannot do
An ARD addresses a defined loss-of-power scenario. It does not remove a mechanical obstruction, repair a door fault or override safety devices that prevent movement. Fire operation, inspection mode and other special conditions must be handled by the approved control design.
Battery condition also matters. Replacement intervals depend on the battery type, environment, usage and manufacturer’s instructions. A general lifespan claim is not a substitute for inspection and testing by the responsible maintenance provider.
If the car remains stopped, passengers should use the emergency alarm or communication equipment and wait for qualified assistance. They should not attempt to force doors or carry out their own rescue.
What to check when specifying an ARD
- Is the rescue system compatible with the proposed motor, drive, controller and door operator?
- Which loads and functions are powered during rescue?
- How are the destination landing and direction selected?
- What happens if the safety circuit is open, battery charge is insufficient or a fault remains active?
- How is battery condition monitored, and what inspection and replacement tasks are required?
- Is rescue testing included in commissioning and the maintenance contract?
- What is the return-to-service procedure after the supply recovers?
Confirm the applicable local requirements and obtain the operating documentation for the exact configuration. For example, the FHSP50 product page lists a battery-powered return function as optional. That listing does not establish the battery capacity, performance or included scope of every installation; obtain confirmation for the lift being quoted.
Choosing the right rescue arrangement
An ARD can reduce the risk of passengers remaining trapped after a power outage when it is correctly selected, installed and maintained. Its purpose, limits and maintenance requirements should be clear before equipment is ordered.
Contact FUJIHD with the proposed lift type, building use and backup-power requirements to discuss a suitable equipment scope.