Do not use an ordinary passenger elevator to escape a fire. Follow the building’s emergency plan, posted instructions and directions from emergency personnel. Specially designed evacuation lifts are an exception only where they are part of an approved evacuation strategy.
This guide explains the difference between ordinary passenger lifts, firefighter lifts and occupant evacuation lifts, and the questions that matter when specifying equipment for a building.
Why ordinary lifts are unsuitable for fire evacuation
A fire can affect a lift’s power supply, electrical equipment, shaft and landing areas. Smoke or water may interfere with operation, and a lift can take passengers toward an unsafe part of the building. A normal passenger lift should not be treated as an escape route simply because it is still moving.
The U.S. Fire Administration’s high-rise guidance tells occupants not to use elevators during a fire because they may become disabled or be reserved by first responders. The applicable building emergency plan determines the safe routes and assistance arrangements for each site.
What lifts may do when a fire alarm sounds
Some installations connect specified fire-alarm signals to a lift recall function. A correctly configured recall sequence can remove the lift from normal passenger service and direct it to a designated landing. The triggering signals, primary or alternative landing and subsequent operation depend on the approved design.
Do not assume every fire alarm activates every lift, that all installations recall in the same way, or that the ground floor is always the designated destination. Building owners should know the documented sequence and arrange coordinated testing with the lift and fire-alarm teams.
Fire-service operation may allow trained firefighters to control designated equipment. The presence of a key switch does not mean the public may use the lift for evacuation, and it does not by itself prove that the complete installation is a protected firefighter lift.
The exceptions
Firefighter lifts
Firefighter lifts are intended to support emergency-service operations under defined conditions. Their suitability depends on the complete building and lift design, which may include protected access, power arrangements, communication and measures addressing water and smoke.
Whether one is required, how it must be designed and who may operate it are questions for the project’s fire strategy, applicable regulations and approving authority. A general article cannot establish those requirements from building height alone.
Occupant evacuation lifts
Some buildings have lifts specifically designed and managed to support occupant evacuation. These require an approved strategy and coordinated building protection and communication arrangements. NFPA distinguishes such systems from ordinary passenger lifts in its high-rise building guidance.
Occupants should use an evacuation lift only as directed by the building’s approved procedures, clear operating instructions or emergency personnel. Do not infer permission from an elevator’s appearance or the fact that its doors are open.
What to do in a fire
- Follow the building’s evacuation or other emergency instructions and directions from responders.
- Use a safe designated escape route when the plan calls for evacuation; do not enter a smoke-filled stairway.
- If you need assistance or cannot use stairs, follow the site’s assisted-evacuation arrangements and tell emergency personnel your exact location. Use a designated refuge area where the building plan provides one.
- Do not use an ordinary lift or attempt to override its controls.
- If you are inside a lift that stops, use its emergency communication equipment and follow responders’ instructions. Do not force the doors or climb out.
What building owners should check
- Which lifts are ordinary passenger lifts, firefighter lifts or approved evacuation lifts?
- What fire-alarm signals and recall actions are documented for each installation?
- Who coordinates testing between the lift, electrical and fire-protection systems?
- Are signs, staff training and assisted-evacuation arrangements consistent with the fire strategy?
- Are protection measures, power supplies and communication arrangements maintained as part of the building system?
Specifying equipment for your building
Start with the approved fire strategy and procurement requirements before choosing a lift configuration. A component label or a generic “fire-rated” claim does not establish that the installed system meets the project’s requirements.
When reviewing FUJI elevator equipment, ask for written confirmation of the functions included and the documentation available for the proposed configuration. Contact FUJIHD with the project specification so the equipment scope can be reviewed alongside your fire consultant, building designer and approving authority.